Four Common Firestopping Mistakes

November 21, 2024

Firestopping is an aspect of building construction that involves sealing openings or gaps in walls, floors, and ceilings to prevent the spread of fire, smoke, and toxic gases. A form of Passive Fire Protection firestopping is highly complex but crucially important, especially as buildings become more sophisticated. Despite this fact, firestopping is often overlooked or improperly installed during construction, leading to potentially catastrophic consequences in the event of a fire. Since most firestopping mistakes are borne from negligence, this paper will highlight ways to avoid these wrong practices so that buildings and its occupants are kept safe and sound

1. Consider the Annular Gap

The annular gap refers to the space between the side of penetration opening and the penetrating material. To prevent spread of water, fire, smoke, and gas, this gap needs to be filled with a tested fire sealant system that allows for expansion, contraction, and movement, and is according to specific test approvals (ETA/BS-EN). Aside from sealants, other types of firestopping materials such as intumescent straps or collars must be installed at the correct depth. If the depth of the material is too shallow, it may not seal the annular gap completely, allowing fire and smoke to still pass through. The best practice is to always follow the instructions of the firestopping system manufacturer carefully.

2. Uncertified Products

Simply put, certified firestopping products provide a higher level of safety and reliability compared to non-certified products. This is because certified firestopping products have been tested and evaluated by independent thirdparty organizations to ensure that they meet specific standards for fire resistance and smoke control. These products have undergone rigorous testing and meet the requirements of building codes and standards. Unlike certified firestopping products which have been tested and approved for their intended use, using uncertified firestopping products can compromise the fire protection system of a building, potentially leading to loss of life, property damage, and legal liability (e.g., cannot claim for fire insurance).

3. Installation Shortcuts

Even the best products, when installed poorly or incorrectly, cannot perform as intended and thereby compromise the integrity of the whole system. The most common shortcuts include using the wrong density of mineral wool, using lesser than the recommended thickness of sealant, using the wrong product in different applications, failing to clean the surfaces to be sealed, not using the proper adhesives, or using a "backer rod" that is too small. All these shortcuts put the building’s structural integrity and its occupants’ safety at risk, not to mention it could lead to code violations and liability issues for building owners, contractors, and installers. Firestopping installation should always be done by trained and certified professionals who underwent the proper product, installation, and technical training by the product manufacturer.

4. Mixing Different Product Brands

Most firestopping products designed by a manufacturer can be used independently or as part of a system because they are compatible when tested together, thereby guaranteeing the most effective passive fire protection while also upholding a valid system warranty. However, if different brands of firestop products are used together, it could compromise the effectiveness of the overall performance of the firestop system because of different properties (e.g., expansion rates or adhesion qualities).


In addition to the risk of decreased fire protection performance, mixing firestopping product brands may not meet building codes and standards, and it can also result in legal and regulatory implications.


More than anything, the best way to avoid any of the above mistakes is to include firestopping early in the building design process. By doing so, it will eliminate so many mistakes during the construction and installation phase, and even provide cost savings if there is no need for remedial work later on.


Blazeout as an independent distributor of Passive Fire and Firestopping products can advise on the solutions required, without having to “push their own brand”. Blazeout can provide impartial advice.

By Jon Richardson April 17, 2026
This blog covers what raised access flooring is as well as the solution to prevent fire spreading through the void. What is Raised Access Flooring (RAF)? Raised access flooring is a system where a floor is installed above a structural subfloor, typically a concrete slab, creating a void between the two levels. This void is used to house and distribute essential building services in a clean, organised and accessible way. What is it used for? The void beneath a raised floor provides space for a wide range of services: - Electrical power distribution - Data and telecommunications cabling - HVAC systems (heating, ventilation and air conditioning) - Fire detection and suppression systems - Security and CCTV cabling - Plumbing and drainage - Environmental controls How is a Raised Access Floor Constructed? A raised access flooring system is made up of modular panels supported by adjustable pedestals arranged in a grid. - Pedestals are fixed to the subfloor and adjusted to create a perfectly level surface - Panels sit on top of the pedestals, forming the finished floor - Stringers (horizontal supports) may be added for extra strength and stability, particularly at higher floor heights. The void beneath the floor can range from as little as 20mm to over 150mm, depending on the project requirements. Can a Raised Access Floor cause a fire hazard in a building? Raised floors create a hidden void (the space underneath), and that introduces a few specific hazards: Cable buildup The void often contains electrical and data cabling. Poorly managed or overloaded cables can overheat and become ignition sources. Airflow spreading fire In many buildings (especially offices and data centres), the void is used for air distribution. That airflow can feed a fire with oxygen and spread smoke or flames quickly. Dust and debris accumulation Dust under the floor is surprisingly flammable. If not cleaned regularly, it can help a small ignition grow. Hidden fire development Fires starting under the floor can go unnoticed longer because they’re out of sight, delaying response. Combustible materials Older or cheaper floor panels and supports may contain materials that contribute to fire load. In modern buildings, much of the critial infrastructure such as cabling, ductwork and services runs unseen beneath raised access floors. While this design offers flexibility and efficiency, it also introduces hidden pathways where fire and smoke can spread rapidly if not properly controlled. This is where the Protecta FR Board RAF Barrier system plays a vital role. What is the Protecta FR Board and RAF Barrier? The Protecta FR Board and RAF Barrier is a robust firestopping solution built using a proven stone wool FR Board system. It is specifically designed to create a secure, certified seal within raised floor cavities. Installed beneath partition walls or across open voids, it helps maintain fire compartmentation and slows the spread of fire and smoke through unferfloor spaces. Why is it important? Raised floor voids can act as a concealed channel, allowing fire, smoke and sound to travel between compartments. By installing a dedicated barrier system: - Fire resistance is maintained beneath partition walls - Large underfloor voids can be subdivided into safer compartments - Critical services such as cables and ductwork remain properly firestopped - Air and sound transfer between spaces is reduced Product Availability The Protecta FR Board RAF Barrier is supplied as standard FR Board panels: 1200x600mm Thicknesses: 50mm, 60mm, 80mm, 100mm For installation, it is used in conjunction with compatable firestopping sealants such as Protecta FR Acrylic and FR Graphite, ensuring a complete and compliant system. All these products are stocked and supplied by Blazeout Ltd. Contact us for project support and material supplies – sales@blazeout.co.uk Free Downloads: Protecta Product Portfolio Protecta Handbook for Timber Construction Protecta Handbook for Linear Seals Protecta Handbook Service Penetrations